Grid of lit office windows in a high-rise building

ENERGY STAR Portfolio Manager (ESPM) does not check your setup against reality. It calculates scores, energy use intensity and emissions from whatever it is given, and it reports those same numbers to the jurisdictions and frameworks that rely on it.

That is why the errors that matter most are rarely typos in a utility bill. They are setup decisions made once, often years ago, that nobody has revisited since. Each one quietly sets the terms for every benchmark comparison, compliance filing and emissions total that follows. EPA’s Data Quality Checker in Portfolio Manager helps with gaps, overlaps and values outside expected ranges, but it cannot tell you whether a setup still matches the building.

The best time to look is before your 2026 data locks. That data will feed benchmarking filings, Local Law 97 reports and GRESB submissions next year, and January 1 starts the 2027 data year that the GRESB 2028 Standards will assess. Here are the five setup errors we find most often, and what to check for each.

1. The property type no longer matches the building

ESPM benchmarks a property against buildings with the same primary use. The ENERGY STAR score compares your building to other buildings nationwide with the same primary use, using a model built for that property type. Get the type wrong and you are measured against the wrong peers.

One property we reviewed was set up in ESPM as a non-refrigerated warehouse. It had been running as a light manufacturing facility for years. Fixing the property type did not change a single meter reading, but it changed how the building compared against national medians, against its portfolio average and against a regulatory threshold.

Property types drift for ordinary reasons: renovations change the use mix, portfolios change hands, configurations get copied forward and placeholders from initial setup never get replaced. In New York, the stakes are now higher still. From calendar year 2026, every Local Law 97 limit is calculated from ESPM property types, so an outdated type sets the wrong emissions cap. We cover that in detail in our post on LL97’s second compliance period.

Check: Does each property use and its floor area still match what is happening inside the building today?

2. Green power is not credited correctly

Onsite solar and offsite green power purchases each need to be configured correctly in ESPM, and the rules for the ENERGY STAR score and for emissions are different. If you own the Renewable Energy Certificates (RECs) from an onsite system, ESPM counts that power as zero emissions. If you sold them, it does not. Offsite purchases show up only in market-based emissions.

The REC terms usually live in a contract, and the ESPM setting lives in a profile. If those two never meet, nobody sees the gap. Our post on green power and RECs in ESPM walks through every combination.

Check: Does the REC ownership setting for each onsite meter match the agreement, and are offsite purchases recorded for the properties they cover?

3. Meters are left out of the whole building numbers

ESPM separates meters into two lists on a property’s Energy tab: Meters Used to Compute Metrics and Additional Meters, Not Used in Metrics. Only the first list drives the score, energy use intensity and the totals reported for compliance.

When a meter lands in the wrong list, or a new meter is added and never selected, the property’s total consumption comes in low. The building did not use less energy. Part of its energy simply never reached the whole building number. NYC’s benchmarking program, for example, asks owners to confirm that every active meter is used to compute metrics, and treats unused active meters as a data quality issue.

Check: Compare the count of active meters with the count used to compute metrics. Any gap needs an explanation.

4. Meters are not mapped to your GHG inventory

The whole building total tells you how much energy a property used. It does not tell you whose emissions they are. For a landlord’s GHG inventory, that answer depends on who controls each meter and on the consolidation approach you use.

Under the GHG Protocol’s operational control approach, a landlord generally reports:

  • Landlord-controlled electricity, such as base building and common areas, in Scope 2

  • Tenant-controlled energy in leased space in Scope 3, Category 13 (downstream leased assets)

Under a financial control or equity share approach, some tenant energy can sit in the landlord’s Scope 1 and 2 instead. Whatever boundary you use, document it.

The practical challenge is keeping the landlord and tenant split current. Tenants turn over, meters are added or swapped and submeter coverage changes after a fit-out. Classifications drift, and so does your inventory.

Check: Is every meter assigned to landlord or tenant control, and is that assignment reviewed when a lease or a meter changes?

5. Ownership and portfolio changes are not reflected

Acquisitions, dispositions and transfers change which properties, and which months, belong in your reporting boundary. When a property changes hands, its ESPM profile is usually transferred or shared, and every setting travels with it, right or wrong.

These changes are easy to record late. That leaves a property in the wrong portfolio for part of the year, a baseline built on someone else’s configuration or a sold asset still sitting in a report.

Check: Are this year’s acquisitions and dispositions reflected, with the right dates, before your baseline data locks for the next reporting cycle?

At a glance

Setup error

What it skews

What to check

Outdated property type

Peer comparison, ENERGY STAR score, LL97 cap

Property uses and floor area by use

Green power misconfigured

Location-based and market-based emissions

REC ownership against contracts; offsite purchases recorded

Meters left out of metrics

Total consumption, EUI, score, compliance totals

Active meters versus meters used to compute metrics

Meters not mapped to the GHG boundary

Scope 2 and Scope 3 split

Landlord or tenant control for every meter

Ownership changes missing

Reporting boundary and baselines

Acquisition and disposition dates

Why this is cheaper to fix now

None of this is glamorous work. But every one of these errors is cheaper to fix now than in the weeks before a filing deadline, when the person who knows the history may be busy and the data is already locked.

The errors also compound. A one-time setup decision becomes the baseline for every year after it, and each year of skewed data makes the correction harder to explain.

How Abisko helps

We keep finding these issues for Abisko clients because of the zero-information-loss integration we have built with ESPM. Abisko syncs with ESPM every night for the 7,000+ properties we support, so property types, meter selections, REC settings and ownership details sit in one view across a portfolio. That vantage point lets us surface these patterns before they compound into years of skewed benchmarking.

What is the least obvious ESPM configuration error your team has run into? If you would like a second set of eyes on your setup before year end, talk to us.

Sources

Chicago • Boston • Brasília

Start your journey. Sign up for product updates, upcoming webinars and more!

Copyright © 2026 Abisko | LinkedIn | Terms & Conditions | Security | info@abisko.io

Chicago • Boston • Brasília

Start your journey. Sign up for product updates, upcoming webinars and more!

Copyright © 2026 Abisko

Chicago • Boston • Brasília

Start your journey. Sign up for product updates, upcoming webinars and more!

Copyright © 2026 Abisko | LinkedIn | Terms & Conditions | Security | info@abisko.io