New York's Local Law 97 cleared its first real test. In the first compliance year, 95% of the Article 320 properties that filed met their 2024 emissions limits, according to the NYC Department of Buildings (DOB).
The second test is much harder. When the 2030 to 2034 limits take effect, caps fall by half or more for most property types. Urban Green Council estimates that only 43% of covered buildings already meet their 2030 limits, based on 2024 benchmarking data.
There is a second change that gets less attention. Starting with calendar year 2026 emissions, reported by May 1, 2027, every building’s limit must be calculated from its ENERGY STAR Portfolio Manager (ESPM) property types. The property type in your ESPM profile is now the foundation your cap is built on.
The 2030 caps by property type
DOB’s rules (1 RCNY §103-14) set LL97 limits by ESPM property type. Here is how the caps change between the first and second compliance periods for common types.
ESPM property type | 2024 to 2029 cap (tCO2e/sf) | 2030 to 2034 cap (tCO2e/sf) | Reduction |
|---|---|---|---|
Office | 0.00758 | 0.00269 | 64.5% |
Financial Office | 0.00846 | 0.00370 | 56.3% |
Multifamily Housing | 0.00675 | 0.00335 | 50.4% |
Hotel | 0.00987 | 0.00385 | 61.0% |
K-12 School | 0.00675 | 0.00223 | 67.0% |
Retail Store | 0.00758 | 0.00210 | 72.2% |
Non-Refrigerated Warehouse | 0.00426 | 0.00088 | 79.3% |
Manufacturing/Industrial Plant | 0.00758 | 0.00142 | 81.3% |
Source: 1 RCNY §103-14. 2030 values rounded to five decimal places.
If you have seen smaller cuts quoted elsewhere, check the basis. The occupancy group limits written into the original law (for example, 0.00846 falling to 0.00453 for Group B offices) are no longer what most buildings will be measured against.
A cleaner grid helps, up to a point
LL97 also lowers the carbon coefficient for grid electricity, from 0.000288962 tCO2e per kWh in the first period to 0.000145 in the second. That is about a 50% drop, so the same electricity use produces about half the counted emissions in 2030.
For most buildings, that is not enough on its own. As an illustration, take an all-electric office sitting exactly at its 2024 to 2029 cap. The cleaner coefficient halves its emissions, but the office cap falls 64.5%. That building would still need to cut its electricity use by roughly 29% to stay under the 2030 cap. Buildings that burn gas or oil on site get no help from the grid coefficient for that share of their emissions.
Your property type now sets your cap
A building’s LL97 limit is the sum of each space’s gross floor area multiplied by the factor for its ESPM property type. So the limit depends on every property use recorded in ESPM, not just the primary one.
For calendar years 2024 and 2025, owners whose ESPM-based limits came out stricter could keep using the original occupancy group limits instead. From calendar year 2026, that option is gone for every building.
That raises the stakes on a field many owners set once and never revisited. We regularly see ESPM property types that no longer match how a building is used:
A property set up as a non-refrigerated warehouse that has run as light manufacturing for years
A mixed-use building where the retail share grew after a renovation, but the ESPM property uses never changed
A placeholder property type from initial setup that stayed in place through an acquisition
None of these are unusual. Under LL97 they now produce the wrong cap, and the error can run either way. In 2030 the Manufacturing/Industrial Plant cap is about 60% higher than the Non-Refrigerated Warehouse cap, so the same building could look compliant or exposed depending on one ESPM field. The penalty for exceeding a cap is $268 per metric ton of CO2e over the limit, so the difference is real money.
What to check before your 2026 report
Confirm every property use. Each space’s ESPM property type should match how it is used today, not how it was used at setup.
Check the floor area split. Mixed-use buildings need gross floor area assigned to each property use, and it changes after renovations and lease-ups.
Use DOB’s definition of gross floor area. It is defined in 1 RCNY §103-14 and is not always the same as the Department of Finance’s gross square feet.
Model your 2030 position now. Run your current energy use against the 2030 caps for your actual property types, using the 2030 electricity coefficient.
Line up capital plans with the calendar. Calendar year 2030 emissions are the first measured against the new caps, and upgrades take time to design, fund and install.
How Abisko helps
To stay ahead of evolving regulations, Abisko lets clients track up-to-date details related to deadlines, exemptions, penalties and more for 150+ benchmarking, BPS and audit & tune-up policies across North America. Because Abisko syncs with ESPM nightly for the 7,000+ properties we support, property types, floor areas and emissions sit in one place, so an outdated property type is easier to spot before it sets the wrong cap.
We are a fast way to see the details and the deadlines, and we always point you to the primary source. For LL97, that means DOB’s rules and the Administrative Code.
If your buildings passed comfortably under the 2024 to 2029 limits, it is worth checking them against the 2030 numbers for your property types. When did your team last review the property types in your ESPM profiles? Talk to us if you would like a second look.
Sources
NYC DOB, 1 RCNY §103-14 (ESPM property type emissions factors and 2030 electricity coefficient)
NYC DOB, Local Law 97: 2024 Compliance and Reporting Rates (2026)
NYC DOB, LL97 reports and ESPM property types (ESPM property types required from calendar year 2026)
NYC DOB, LL97 presentation (limit calculation by property type and the gross floor area definition)
NYC DOB, LL97 presentation, March 2024 ($268 per ton penalty)
Urban Green Council, Local Law 97 progress (updated January 2026)